+86-21-58386256

A RECOMMENDED SYNTHETIC COARSE AGGREGATE CLASSIFICATION ...

the dry loose unit weight is used as a quality acceptance criteria. it is recommended that the dry loose weight determination be made in accordance with tex-404-a, except that the aggregates shall be tested in an oven-dry condition.

Fall 2016 Structural Testing Laboratory (CVEN 3400) Final Exam

Design a lightweight concrete mix for a 29.74815 MPa building column of a multistory structure subjected to freezing and thawing during construction with Type I non-air-entrained cement, "the oven-dry loose weight of coarse aggregate" = 6283.4986 N/m 3 with a specific gravity factor of 1.90 and an absorption of 12.4 percent with a size of 1 ...

Bulk Density Of Aggregates | Loose And Compact Bulk ...

Jul 30, 2012· If a statement is like: A coarse aggregates with higher bulk density, then it means few of the voids can be filled by using fine aggregates and cement. For testing, British Standard (BS 812) has specified the degree of compaction. These are; Loose ( Un-compacted) Compacted; The test will be carried out by using metal cylinder having prescribed depth and …

Fine Aggregate Specific Gravity – Pavement Interactive

The mass of a fine aggregate sample is determine in SSD, oven-dry and submerged states. These values are then used to calculate bulk specific gravity, bulk SSD specific gravity, apparent specific gravity and absorption. Figure 5 shows the major equipment used to perform the FASG test. Figure 5: Major equipment used in performing the FASG test.

IS 2386-3 (1963): Methods of test for aggregates for ...

Is:2386(PartIll)-1963 2.2 Method I - Aggregate Larger than 10 mm 2.2.1 4 b! 4 4 4 f > g> Apparatus - The apparatus shall consist of the following: Balance -A balance or scale of capacity not less than 3 kg, readable and accurate to O-5 g and of such a type and shape as

FIELD SAMPLING AND TESTING MANUAL TESTING …

For coarse aggregate or composite of coarse and fine aggregate, sample from trucks. Take samples from a m inimum of three trenches. Dig trenches across ... Oven dry the sample according to ND T 255 at a temperature of 230 ± 9°F (110 ± 5°C). Weigh and record as original weight of sample.

One Thing: Aggregate Moisture Content Testing - NPCA

Jan 17, 2019· If using an oven, place the sample container with the aggregate inside the oven first and then turn on the oven. Rapid heating of coarse aggregate can cause some particles to explode, which is both a safety concern and will result in the loss of aggregate particles and skew the testing results.

SPECIFIC GRAVITY AND ABSORPTION OF FINE AGGREGATE

The specific gravity may be expressed as bulk oven dry (O.D.) specific ... 1.5 When the specific gravity and absorption of the fine aggregate and the coarse aggregate are known, the combined aggregate specific gravity and absorption is determined, if necessary, utilizing Arizona Test Method 251. ... Remove loose material ...

SATURATED SURFACE-DRY SPECIFIC GRAVITY AND …

6.2.27 Dry the aggregate to constant mass in an oven, then cool to room temperature and weigh. 6.2.28 Record the net oven-dry mass of the sample to the nearest 0.5 g as X 1 under Section 7. 6.2.29 Keep the excess saturated surface-dry material sealed in …

what is the meaning of aggregate|what is coarse aggregate

Apr 21, 2020· Aggregate in general consists of both fine and coarse inert materials used in the manufacture of concrete. Fine aggregate is aggregate all of which passes through 4.75 mm IS sieve. Coarse aggregate is aggregate most of which is retained on 4.75 mm sieve. As I am too Civil Engineer so one tip for all my new Civil Engineer Readers that, All fine ...

Why do we need to dry the aggregate (coarse) before ...

Answer: because aggregate is generally not dried, therefore the aggregate moisture content will affect the water content (and thus the w/c also) of the produced PCC and the water content also affects aggregate proportioning (because it contributes to aggregate …

Bulk Density and Voias of Coarse Aggregate - YouTube

Sep 02, 2013· About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features Press Copyright Contact us Creators ...

(PDF) Equations for Mix Design of Structural Lightweight ...

Oven dry loose weight of coarse aggregate = 769 kg/m3 (Nawy, 2001). 3.2. Case 2: Volume method A lightweight aggregate concrete containing normal weight fine aggregate is required to have a compressive strength (measured on standard cylinders) of 30 Mpa and a maximum air-dry density of 1700 kg/m3. Compliance with the density requirement is ...

(PDF) Full Thesis | al amin - Academia.edu

2) The fine aggregate from the pycnometer has been removed and dried to constant weight at a temperature of 110 ± 50C (230 ± 90F), cool in air at room temperature for 1 ± 1/2 hrs and weight. 3) The weight of the pycnometer filled to its calibration capacity has been determined with water at 23 ± 1.70C (73.4 ± 30F).

DIVISION 9 – MATERIALS

Provide coarse aggregates for Portland cement concrete in accordance with Table 902-1, Table 902-2, and this subsection. A. Slag Coarse Aggregate. Use slag coarse aggregate consisting of iron blast furnace slag or reverberatory furnace slag with a dry (loose measure) unit weight of at least 70 pounds per cubic foot in accordance with MTM 123. B.

CHAPTER 3 - PHYSICAL PROPERTIES OF LIGHTWEIGHT …

TABLE 3.2—Requirements of ASTM C 330, C 331, and C 332 for Dry Loose Bulk Density of Lightweight Aggregates. Aggregate Size and Group Maximum Dry Loose Bulk Density kg/m 3 3(lb/ft ) Minimum Dry Loose Bulk Density kg/m3 (lb/ft ) ASTM C 330 AND C 331 fine aggregate …

SECTION 706 AGGREGATES FOR PORTL AND CEMENT …

Unit Weight (loose oven dry) Fine Aggregate 70 lb/ft 3 Nev. T487 Maximum 706.03.02.A.2 below Unit Weight (loose oven dry) Coarse Aggregate 55 lb/ft 3 Unit Weight (loose oven dry) Combined Fine and Coarse Aggregate 65 lb/ft 3. AGGREGATES FOR PORTLAND CEMENT PRODUCTS 706 706-5 Table 7 - Lightweight Aggregate Properties

1. SCOPE AASHTO T 19 NOTE: 2 2.1.

of the coarse aggregate approximately balance the larger voids in the surface below the top of the measure. 7.2. Determine the mass of the measure and its content and record the net mass of the aggregate to the nearest 0.1%. Using the calibration factor of the measure, determine the loose unit mass of the aggregate.

Moisture Content

Oven-dry (OD): All moisture is removed from the aggregate by heating in an oven at 105 C to constant weight (overnight heating usually is sufficient). All pores are empty. Air-dry (AD): All moisture removed from surface, but internal pores partially full. Saturated-surface-dry (SSD): All pores filled with water, but no film of water on the ...

Moisture Content – Pavement Interactive

In general, there are four aggregate moisture conditions: Oven-dry (OD). All moisture is removed by heating the aggregate in an oven at 105 ° C (221 ° F) to constant weight (this usually constitutes heating it overnight). All pores connected to the surface are empty and the aggregate is fully absorbent. Airdry (AD).

Sieve Analysis of Fine and Coarse Aggregates

obtained from an ignition oven or extraction sample. 3.2 Place a representative sample of processed aggregate in oven and dry to constant weight at a minimum temperature of 225°F (107°C). 3.2.1 For field testing of portland cement concrete aggregate, it is not necessary to completely dry, but merely to surface dry, the coarse aggregate.

Fundamentals of Concrete

The weight of the aggregate is measured and divided by the volume of the container to yield the dry rodded unit weight in terms of weight per volume such as pounds per cubic foot. By knowing the dry rodded unit weight of a nominal maximum size coarse aggregate and the fineness modulus of the fine aggregate, the weight of the coarse aggregate ...

(PDF) ACI 211.2 | Menoo Nash - Academia.edu

The batch weights for a 1.0 ft3 batch are calculated as follows: The oven-dry loose weight of coarse aggregate is found to Cement 610/27 = 22.59 lb be 47 lb/ft3. Employing the sequence outlined in Section 3.2.2, the quantities of ingredients per yd3 of concrete are Fine aggregate (SSD) 1079/27 = 39.96 lb calculated as follows: Coarse Aggregate ...

SPECIFIC GRAVITY AND ABSORPTION OF FINE AGGREGATES …

accordance with AASHTO T 248 (Reducing Field samples of Aggregates to Test Size). The sample size for this procedure is approximately 1000g of material passing the No. 4 (4.75 mm) sieve. 2. Dry test samples to constant weight in an oven set at 230 ± 9°F (110 ± 5°C). Cool the sample at room temperature for 1 to 3 hours. After the cooling period,

DETERMINING UNIT MASS (WEIGHT) OF AGGREGATES

3.4 If oven dry condition is desired, place the sample in a 110 5 C (230 9 F) oven until constant mass is obtained. Cool to room temperature. 3.5 If SSD condition is desired, air dry at room temperature to the SSD condition. 4. PROCEDURES 4.1 Determining Unit Mass (Weight)—Loose Method: 4.1.1 Coarse Aggregate:

EXPANDED SHALE CLAY AND SLATE LIGHTWEIGHT …

Dry Loose Density – ASTM D 4254 or "Minimum Index Density" This test is used to determine the minimum index dry density of oven-dried cohesionless, freedraining soils that - contain up to 15%, by dry mass, of particles passing a #200 sieve. There are three acceptable methods, but only the most common, Method A, is shown here:

SPECIFIC GRAVITY OF COARSE AGGREGATE AASHTO T 85

(4.75 mm) material). Wash the aggregate retained on the No. 4 (4.75 mm) sieve. 3. Dry test sample to constant weight in an oven regulated at 230 ± 9°F (110 ± 5°C). Cool sample at room temperature for 1 to 3 hr. After the cooling period, immerse the aggregate in water at room temperature for a period of 15 hr. 4.

SPECIFIC GRAVITY AND ABSORPTION OF COARSE …

coarse aggregate. The specific gravity may be expressed as bulk oven dry (OD) specific gravity, bulk saturated surface dry (SSD) specific gravity, or apparent specific gravity. The bulk (SSD) specific gravity and absorption are based on aggregate …

loose bulk density of aggregates test procedure - BINQ Mining

Feb 12, 2013· dry loose bulk density of coarse aggregate – ASTM C29 / C29M – 09 Standard Test Method for Bulk Density … Density (Loose) (Test Method C 29)- The aggregate shall be tested in an oven dry … »More detailed

Bulk Density and Void Percentage Test for Aggregates - The ...

Method A Rodding for maximum aggregates size of 37.5 mm or less, Method B—Jigging for maximum aggregates size greater than 37.5 mm and not exceeding 125 mm, and Method C—Shoveling to determine the loose bulk density of the aggregate. Method A: Rodding. Fill the measure with aggregate in nearly equal three layer.